SCBX Heating Cable

Parallel circuit heating cable – Constant watt for hazardous areas

Certificate NO SIRA 03 ATEX 3376U ex

Heating Cable SCBX Data sheet – Data Sheet

>> Parallel circuit heating cable is designed to be cut from reel lengths and site terminated to suit pipework. The heating cable consists of a number of short heating zones, each connected across a pair of continuous bus-wire conductors.

Each complete heating zone will give its full rated design output with circuit voltage applied to the bus-wire conductors.

Construction

The heating cable has a core comprising two bus-wire conductors contained within an extruded silicone rubber sheath. The sheath is notched on alternate sides at predetermined intervals to expose a short section of bus-wire conductor.

Nickel-chromeresistance wire is wrapped at regular spacing around the core as a continuous conductor, making contact with the bus-wires at the exposed points.

After completion of the heater conductor wrapping, a high temperature soldered joint is made at each contact point ensuring that a number of conductor strands are securely bonded to the bus-wires.

An extruded outer sheath of silicone rubber is then placed over the core and heater element to complete the heater cable assembly.

Web Inquiry

Spam Protection
Enter a number between one and nine! (required field) *



scbx heatingcable

Range
Type Volts Watt/m Heather zone length (m) Max circuit length (m)
SC 8 110 8 1,0 110
SC 12 110 12 1,0 80
SC 16 110 16 1,0 75
SC 20 110 20 1,0 69
SC 30 110 30 1,0 60
SC 8 240 8 1,0 250
SC 12 240 12 1,0 170
SC 16 240 16 1,0 145
SC 20 240 20 1,0 120
SC 30 240 30 1,0 105
 Specification
Conductors Copper stranded flexible -30/0,25mm (1,5mm²)
Core Silicone rubber
Heater element Nickel-chrome 80-20
Solder High melting point 296°C
Outer sheath Silicone rubber
Width 13,3mm (Braided version)
Thickness 9,5mm (Braided version)
Heater zone 1m
Braid Tinned copper
Temperature range -60°C to +200°C
Standard To BS EN 60079
Min bend radius 25mm

ex SIRA 03ATEX3376U

 Electrical

scbx-electrical

A 30mA trip Residual Current Circuit Device (RCCD) or Earth Leakage Circuit Breaker (ELCB) is recommended for use with heating cables.

 

Maximum temperature within appropriate T class
Type Maximum temperature of surface to be heated ˚C within
Appropriate T class
T6 T5 T4 T3
SCBX 8 110V 52 70 112 188
SCBX 12 110V 50 95 173
SCBX 16 110V 76 158
SCBX 20 110V 55 144
SCBX 30 110V 80
SCBX 8 240V 52 70 112 187
SCBX 12 240V 50 95 173
SCBX 16 240V 76 158
SCBX 20 240V 55 144
SCBX 30 240V 93

IHP works together with many leading industrial companies in Europe. As a partner and supplier, we are known for our flexibility and our high quality products and services. IHP has a business valued model and creates successful long-term relationships.

clients

IHP AB

Hällebergsvägen 5
SE-443 60 Stenkullen
Sweden

   Switch:
   Fax:
   E-mail:
   Skype:
+46 (0)31 795 30 30
+46 (0)31 795 30 39
info@ihpheating.com
ihpmeeting
Opening Hours
Monday 07:30-16:00
Tuesday 07:30-16:00
Wednesday 07:30-16:00
Thursday 07:30-16:00
Friday 07:30-16:00
Saturday Closed
Sunday Closed

Copyright © IHP AB 2005-2019. All rights reserved.
Sitemap

Our offices